Generac Power Systems 5448 Details and Specifications
GenReady Basic Load Center & Transfer Switch, Nema 1
The advanced Engineering of the GenReady Load Center replaces the home's main circuit panel and incorporates the automatic transfer switch in the form of the EZ Transfer Operator (p/n 5447). All power switching is handled within one unit, so it becomes a hybrid circuit panel capable of separating out only the electrical circuits chosen to be ocvered during a power outage.
The BASIC GenReady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. Installed without the EZ Transfer Operator (p/n 5447) , the GenReady Basic prepares you for a future generator installation.
Features:
• Rated 200 Amp
• 40 Circuit capacity with the use of tandem breakers
• Dimensions are about the same as a standard 42 space main load center
• Utilizes standard Siemans components
• Protect up to 18 circuits, up to 30 with the use of tandem breakers
• 10 Circuits available for non-protected loads
• Circuits can easily be shifted from protected to non-protected and vice versa
• UL Listed and Service Rated
• Single panels are compatible with generaotrs rated up to 125 Amps/30kW
• Flush Mount Nema 1 Enclosure (Indoor Only)
Includes:
• 125A Circuit Breaker
• 125A Lower Panel Circuit Switch
• 200A Main Circuit Breaker
The advanced Engineering of the GenReady Load Center replaces the home's main circuit panel and incorporates the automatic transfer switch in the form of the EZ Transfer Operator (p/n 5447). All power switching is handled within one unit, so it becomes a hybrid circuit panel capable of separating out only the electrical circuits chosen to be ocvered during a power outage.
The BASIC GenReady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. Installed without the EZ Transfer Operator (p/n 5447) , the GenReady Basic prepares you for a future generator installation.
Features:
• Rated 200 Amp
• 40 Circuit capacity with the use of tandem breakers
• Dimensions are about the same as a standard 42 space main load center
• Utilizes standard Siemans components
• Protect up to 18 circuits, up to 30 with the use of tandem breakers
• 10 Circuits available for non-protected loads
• Circuits can easily be shifted from protected to non-protected and vice versa
• UL Listed and Service Rated
• Single panels are compatible with generaotrs rated up to 125 Amps/30kW
• Flush Mount Nema 1 Enclosure (Indoor Only)
Includes:
• 125A Circuit Breaker
• 125A Lower Panel Circuit Switch
• 200A Main Circuit Breaker
Ships Free with a Generator or $48.00 Shipping Fee Will Be Added